Project Highlight – UC Berkeley Bakar Bioenginuity HUB Dekker Laboratory Vacuum …

//
Comments0
  • Design Criteria:
    • 115 Lab Vacuum Turrets.
      • 30 SCFM @ 25”HGVAC
    • Design per ASPE Laboratory Vacuum System Design Guidelines
  • AES-Dekker Laboratory Vacuum System Model AES-VMXVFD0303KA2-00-ES
    • (2) Dekker Titan single stage 20HP liquid ring vacuum pump skids.
      • 83 SCFM @ 25”HGVAC (Each Vacuum Pump)
    • System Components Include:
      • (2) TEFC Electric motors, 230/460 Volt, 3 Phase, Premium Efficiency.
      • (2) Flexible Couplings
      • (2) Fabricated Steel Baseplates Mounted on Common Base.
      • (2) Patented DX5 Discharge Separator-Reservoirs with 5 Stage Air/Oil Separation, Including Coalescing Filter.
      • (2) Seal Fluid Isolation Valves
      • (2) Y-Strainers
      • (2) Service Liquid Solenoid Valves, 24VDC.
      • (2) Separator Drain Valves
      • (2) Separator Sight Level Gauges
      • (2) Temperature RTD for Discharge Temperature Indication and High Temperature Protection.
      • (2) High/Low Oil Level Switches
      • (2) Air-Cooled, Heat Exchanger Packages with Main Motor Driven Fan and Fan Guard.
      • (2) Inlet Check Valves
      • Inlet Manifold Including:
        • (2) Inlet Isolation Valves
        • (2) Inlet Flex Connectors
        • Manifold Piping
      • Discharge Manifold Including:
        • (2) Individual Pump Drip Legs
        • (2) Discharge Check Valves
        • (2) Discharge Flex Connectors
        • Manifold Piping
      • (2) Sets of Hydraulic Hose Seal Fluid Line.
      • (3) Inlet Filters-Solberg ST-HV Series 3” (Specification and Data Sheet Attached)
        • Activated Carbon Granulate -ACG Media
          • Removes Gaseous or Vapor Odors
        • Note (1) Inlet Filter Shipped Loose for Field Installation
      • (2) Vacuum Relief Valves
    • Vacuum Receiver
      • (1) Vertical Vacuum Receiver 200 Gallon.
      • (1) Receiver Sight Level Gauge
      • (1) Receiver Drain Valve
      • (1) Receiver Isolation Valve
    • Electrical:
      • (1) Duplex ControlDEK Control Panel
        • Monitors, measures and displays performance
        • Identifies maintenance and fault conditions, prevents downtime, and preserves system quality.
        • Standard 460V, 3 Phase, 60Hz (NEMA12, CUL Listed
        • Custom PLC with 4.3” Color Touchscreen LCD with integral hour meter
        • Across-line Magnetic Vacuum Pump Starter with 3 Phase Overload Protection
        • RTD for discharge temperature indication and high temperature protection
        • Vacuum On/Off capability with adjustable set points
        • Vacuum transducer, for vacuum level indication
        • Pressure transducer, for back pressure indication
        • 24V Power Supply
        • (1) VFD to be on the “Lead” Pump and Provide Alternate “Lead” Programming Logic.
        • BacNet and Dry Contacts Included

 

*We offer preventative maintenance programs that are created for your specific systems/equipment and the needs of your facility. We also perform repairs/rebuilds, troubleshooting and emergency site visits. AES provides service reports, for easy access of system information and any service or repair completed on your equipment. (example AES Service Report).

We also have O&M Manuals (example RVL051H O&M Manual) and parts break downs (example RVL051H Maintenance Parts) to help you find the recommended parts needed for maintaining your equipment. We carry a variety of brands and parts in our  Shop, if you don’t see what you need, let us know and we will find it for you.